Objective. Students will select the correct AWS ER-series wire classification and shielding gas mixture for a given base metal, thickness, and transfer mode by applying AWS A5.18 filler metal specifications and published gas selection charts.
Gas Metal Arc Welding (GMAW) uses a continuous solid wire electrode fed through a gun, a shielding gas to protect the weld pool from atmospheric contamination, and a constant-voltage (CV) DC power source. Choosing the right wire and gas combination for your base metal and application is not guesswork—it is guided by AWS A5.18, the filler metal specification for carbon steel electrodes for GMAW, and by published gas selection data.
Every GMAW wire for carbon steel carries an AWS designation under A5.18. The letters and numbers each mean something specific:
ER70S-3 has a moderate deoxidizer content (silicon and manganese). It performs well on clean, mill-scale-free base metal. It is the economical choice for fabrication shops where the steel is prepped thoroughly.
ER70S-6 has higher silicon and manganese deoxidizer levels. Those extra deoxidizers let it handle mill scale, light rust, and surface contaminants better than ER70S-3. For structural and construction work where steel arrives with mill scale, ER70S-6 is the common field choice. Both classifications meet the 70,000 psi minimum tensile requirement and are fully compatible with each other for most structural applications.
Wire diameter affects deposition rate, heat input, and transfer mode. Common diameters are 0.030" and 0.035". Smaller diameters (0.030") are used for short-circuit transfer on thinner material; larger diameters (0.035" and up) handle heavier material and higher-deposition spray transfer.
The shielding gas keeps oxygen and nitrogen out of the weld pool. Different blends produce different arc characteristics, spatter levels, and penetration profiles.
100% CO₂ is the lowest-cost option. It produces deep penetration and is widely used in production welding. The downside is a rougher, more spattery arc because CO₂ is an oxidizing gas that disrupts the arc plasma. It limits you to short-circuit and globular transfer; true spray transfer does not occur with 100% CO₂.
C25 (75% Argon / 25% CO₂) is the most popular blend for structural mild steel. The argon stabilizes the arc, reducing spatter dramatically compared to 100% CO₂ while still providing good penetration. C25 supports short-circuit transfer at lower parameters and can achieve spray transfer at higher parameters.
98/2 (98% Argon / 2% O₂) is an argon-rich blend used primarily for spray transfer on clean carbon steel and some stainless applications. The tiny oxygen addition stabilizes the arc without excessive oxidation.
The transfer mode describes how metal crosses the arc from wire to weld pool. Your voltage, amperage, and gas blend together determine which mode occurs.
Short-circuit transfer operates at low voltage and low amperage. The wire tip physically contacts the puddle, creating a short circuit that melts the wire tip; the cycle repeats up to hundreds of times per second. The result is a small, fast-freezing weld pool—ideal for thin material, out-of-position welding, and root passes. The arc sounds like a crisp, consistent buzzing or bacon frying. Spatter is low when parameters are dialed in correctly.
Globular transfer occurs at intermediate voltage and amperage, most commonly with 100% CO₂. Large, irregular droplets fall across the arc under gravity. Spatter is high, penetration is moderate, and the arc sounds harsh and irregular. It is generally considered undesirable for structural work but may appear when parameters drift between modes.
Spray transfer requires higher voltage and amperage and an argon-rich gas (at least 80% Ar). Metal transfers as a fine, continuous stream of tiny droplets. The result is a smooth, stable arc with very low spatter, high deposition rates, and good fusion. The arc sounds like a soft hiss. Spray transfer is limited to flat and horizontal positions because the high heat input produces a fluid puddle that cannot be controlled out of position.
Shielding gas cylinders are high-pressure vessels. Handle them as follows:
Always verify that the regulator is rated for the specific gas in the cylinder. CO₂ regulators include a heater or are CGA-320 fittings; argon/mixed-gas regulators use CGA-580 fittings. Never interchange them.
Answer each question, then check it. Nothing is recorded; this is your own practice.
A free tech program — complimentary, as our commitment to get America working. Help us build VoTechWorks. Tell us what works, what doesn’t, and what you want to learn.
Does the school offer financial aid?
No. We don’t offer financial aid because we’re free. No, really: completely free.
Do you offer industry certification?
No. We are not certified yet, so we can’t offer that to students. What we do offer is knowledge and understanding of a trade.
Enroll first in the trade you’re interested in. You get your key, your program opens, and you begin studying.
Enroll free →