Objective. Students operate a spectrum analyzer to identify signals by frequency and amplitude, use an RF power meter to measure forward and reflected power, and use a cable/TDR analyzer to locate a fault in a coaxial cable.
This lesson, its worked examples and its practice questions has not yet been verified by an industry-certified professional or by a certification or approval body. It is a study draft and may contain errors. Do not use it as instructions for work on a job site or on live equipment. Always follow your instructor, your supervising professional, and current official references and regulations.
VoTechWorks program approval and accreditation are still in progress. Credentials are issued only by the certifying bodies named in each program, after their own exams.
RF technicians rely on three core instruments to install, verify, and troubleshoot radio-frequency systems: the spectrum analyzer, the RF power meter, and the cable/TDR analyzer. Each answers a different question. The spectrum analyzer shows what signals are present and where in frequency they sit. The power meter tells you how much power is flowing and how much is being reflected. The TDR (time-domain reflectometer) or cable analyzer tells you where a fault lies in a transmission line. Mastering all three is essential for the ETA CET and FOI/FOT exams, the BICSI Installer credential, and daily field work.
A spectrum analyzer displays signal amplitude (vertical axis, usually in dBm) versus frequency (horizontal axis). Before you capture any signal, set four controls:
When reading signals, report center frequency and peak amplitude together (for example, "98.1 MHz at −22 dBm"). Record every reading in your lab notebook with date, instrument ID, and settings — this is required for professional documentation and for credential exam scenarios.
Safety: Never connect an unknown signal source directly to a spectrum analyzer input without a power attenuator or checking the maximum input level. Exceeding the rated input power destroys the input stage instantly. Keep the instrument away from energized high-voltage equipment. Follow all lab safety signage.
An RF power meter with a dual-directional coupler samples power traveling in both directions on a transmission line simultaneously. Forward power (P_F) travels from the transmitter toward the load; reflected power (P_R) travels back toward the transmitter when the load impedance does not match the line impedance (typically 50 Ω).
From these two readings you calculate standing wave ratio (SWR):
1. Find the reflection coefficient magnitude: Γ = √(P_R / P_F)
2. Then: SWR = (1 + Γ) / (1 − Γ)
A perfect match gives SWR = 1.0:1. A 2:1 SWR means about 11% of forward power is reflected — tolerable for many systems but worth investigating. Higher SWR wastes transmitter power, can damage final amplifier stages, and reduces system range.
Safety: Use only a calibrated dummy load or approved test load. Never operate a transmitter without a load — even briefly — unless the manufacturer's specification explicitly permits it. Verify the power meter and coupler are rated for the frequency and power level in use before connecting any source.
A TDR works by injecting a fast electrical pulse into a cable and measuring the time until a reflection returns. Any impedance discontinuity — an open circuit, a short circuit, a damaged connector, or a kink — causes a reflection. Because the signal travels at a known velocity of propagation (VoP), the instrument converts round-trip time into distance:
Distance = (VoP × c × t) / 2
where c is the speed of light in a vacuum (approximately 3 × 10⁸ m/s), t is the measured round-trip time, and VoP is the cable's velocity factor (a decimal, for example 0.66 for standard RG-6 coax). You must enter the correct VoP for the cable type before taking a reading; an incorrect VoP produces a proportionally wrong distance result.
The screen displays a waveform: a positive spike indicates an open-circuit fault; a negative spike indicates a short-circuit fault. The horizontal axis reads out in feet or meters directly on most modern instruments.
Safety: Before connecting a TDR to any installed cable, confirm via lockout/tagout or visual inspection that no live RF or DC voltage is present on the cable. TDR pulses are low-energy, but an energized cable can damage the instrument and harm the user. Wear appropriate PPE in any equipment room or cable vault.
For every test, record: instrument make/model and serial number, calibration due date, cable type and length, all settings used, and the raw readings before any calculated result. BICSI and ETA both expect technicians to maintain traceable records. In the field, these records protect you legally and help the next technician service the system correctly.
The spectrum analyzer, power meter, and TDR/cable analyzer form the core RF test toolkit. Set instrument controls correctly before measuring, record all data in a lab notebook, verify your arithmetic when calculating SWR or TDR distance, and always observe power ratings and lockout/tagout procedures. These habits satisfy both credential exam requirements and real-world employer expectations.
Answer each question, then check it. Nothing is recorded; this is your own practice.
A free tech program — complimentary, as our commitment to get America working. Help us build VoTechWorks. Tell us what works, what doesn’t, and what you want to learn.
Does the school offer financial aid?
No. We don’t offer financial aid because we’re free. No, really: completely free.
Do you offer industry certification?
No. We are not certified yet, so we can’t offer that to students. What we do offer is knowledge and understanding of a trade.
Enroll first in the trade you’re interested in. You get your key, your program opens, and you begin studying.
Enroll free →