Objective. Students will identify the fumes and gases generated by common welding processes and base metals, read a Safety Data Sheet (SDS) for a welding consumable, and select appropriate ventilation and respiratory protection controls in compliance with ANSI Z49.1 and OSHA PELs.
Every welding arc vaporizes base metal and consumable alike. Those vapors cool instantly into microscopic solid particles — welding fume — that float in the breathing zone long after the arc stops. At the same time, shielding gases, combustion products, and coating decomposition release invisible gases such as carbon monoxide, nitrogen oxides, and ozone. Breathing either fumes or gases above safe limits damages the lungs, nervous system, and other organs. Protecting yourself starts with knowing what the specific process and base metal produce.
SMAW (Stick welding): The flux coating burns and generates fume that includes iron oxides, manganese, and silicates. Low-hydrogen electrodes such as E7018 also release fluorides. Manganese exposure is of particular concern because chronic overexposure can cause neurological damage.
GMAW (MIG welding): The shielding gas (CO₂ or argon/CO₂ mixes) displaces oxygen in enclosed spaces and produces carbon monoxide and ozone near the arc. The wire itself contributes iron oxide and manganese fume.
FCAW (Flux-core): Combines features of both processes above; flux-core wires often produce higher fume generation rates than solid wire GMAW and release additional fluorides from certain wire types.
Base metal factors: Galvanized steel releases zinc oxide fumes that can cause metal fume fever — a temporary flu-like illness. Stainless steel and chrome-moly alloys generate hexavalent chromium (Cr(VI)), a confirmed human carcinogen. Coated or painted surfaces may release lead, cadmium, or other toxic substances. Always identify the base metal and any surface coating before striking an arc.
The SDS is your primary source of hazard information for any welding consumable. Under the OSHA Hazard Communication Standard (29 CFR 1910.1200), manufacturers must provide a 16-section SDS for every hazardous product.
For welding purposes, focus on:
The PEL is a legally enforceable limit set by OSHA. The TLV is an advisory guideline published by ACGIH, typically more current and often more protective. When they differ, the TLV is the better benchmark for hazard control planning.
ANSI Z49.1, Safety in Welding, Cutting, and Allied Processes, is the foundational consensus standard for welding safety. It requires adequate ventilation whenever welding is performed, with the level of control matched to the hazard.
General ventilation moves large volumes of shop air to dilute fumes across the whole space. It is the minimum acceptable approach for low-hazard operations on mild steel in open shops, but it does not reliably protect the welder because fume passes through the breathing zone before it is diluted.
Local exhaust ventilation (LEV) captures fume at or near the source before it reaches the welder's face. An LEV hood positioned within a few inches of the arc and pointed so the plume flows away from the welder's face is far more effective than general ventilation. The capture velocity — the air speed at the hood face needed to pull fumes in — must overcome ambient air currents. Smoke tubes demonstrate capture velocity visually: the smoke trail shows whether the hood is drawing fumes in or whether they escape into the breathing zone.
Confined-space ventilation is the most demanding scenario. ANSI Z49.1 Section 4 addresses confined and restricted spaces and requires supplied fresh air (not oxygen enrichment) at a rate sufficient to keep contaminants below PELs, prevent oxygen deficiency, and prevent accumulation of flammable gas. Positive-pressure ventilation with a blower forcing fresh air in, combined with a separate exhaust path, is the standard approach.
When engineering controls alone cannot reduce exposures to or below PELs, respirators are required under OSHA 29 CFR 1910.134.
Always apply controls in order: Elimination (choose a lower-fume process if possible) → Substitution (use a lower-manganese wire) → Engineering controls (LEV, general ventilation) → Administrative controls (rotate workers, limit arc-on time) → PPE (respirators). Respirators are the last line of defense, not the first.
Answer each question, then check it. Nothing is recorded; this is your own practice.
A free tech program — complimentary, as our commitment to get America working. Help us build VoTechWorks. Tell us what works, what doesn’t, and what you want to learn.
Does the school offer financial aid?
No. We don’t offer financial aid because we’re free. No, really: completely free.
Do you offer industry certification?
No. We are not certified yet, so we can’t offer that to students. What we do offer is knowledge and understanding of a trade.
Enroll first in the trade you’re interested in. You get your key, your program opens, and you begin studying.
Enroll free →